Pumpar horisontella flerstegs elektriska pumpar ROVATTI ME100KX100-100 

Pumpar horisontella flerstegs elektriska pumpar ROVATTI ME100KX100-100
Viskositet 1 mm²/s
Temperatur 20°C,
η% - Pump effektivitet, Y Ventilförlust returnerar inte.
ME100KX100-100 - 2 Poler | ||||||||||||||||||
Pump | IEC | A | B |
C |
D | E | F | G | H | L | M | N | P | Q | R | S | Pump Vikt | Motor Vikt |
ME30KX100-100/2 | • | 204 | 312 | 358 | 350 | - | - | - | - | - | - | - | - | - | - | - | 77 | * |
ME35KX100-100/2 | • | 204 | 312 | 358 | 400 | - | - | - | - | - | - | - | - | - | - | - | 80 | * |
ME40KX100-100/2 | • | 204 | 312 | 358 | 400 | - | - | - | - | - | - | - | - | - | - | - | 80 | * |
ME50KX100-100/2 | • | 204 | 312 | 358 | 400 | - | - | - | - | - | - | - | - | - | - | - | 80 | * |
ME60KX100-100/3 | • | 289 | 312 | 127 | 450 | - | - | - | - | 900 | 1250 | 175 | 325 | 545 | 555 | 585 | 138 | * |
ME75KX100-100/3 | • | 289 | 342 | 68 | 550 | - | - | - | - | 900 | 1250 | 175 | 350 | 570 | 555 | 585 | 148 | * |
ME75KX100-100/4 | • | 373 | 342 | 3 | 550 | - | - | - | - | 920 | 1270 | 175 | 350 | 570 | 555 | 585 | 151 | * |
ME100KX100-100/4 | • | 373 | 342 | 118 | 550 | - | - | - | - | 1021 | 1521 | 225 | 380 | 600 | 620 | 650 | 174 | * |
ME100KX100-100/5 | • | 458 | 342 | 33 | 550 | - | - | - | - | 1021 | 1521 | 225 | 380 | 600 | 620 | 650 | 184 | * |
ME125KX100-100/5 | • | 458 | 342 | 33 | 550 | - | - | - | - | 1021 | 1521 | 225 | 380 | 600 | 620 | 650 | 184 | * |
Pump typ | Motor effekt | Kapacitet | ||||||||||
[l/min] | 0 | 400 | 1300 | 1600 | 1700 | 1900 | 2000 | 2100 | 2300 | |||
[m3/h] | 0 | 24 | 78 | 96 | 102 | 114 | 120 | 126 | 138 | |||
IEC | [kW] | [I/s] | 0 | 6,7 | 21,7 | 26,7 | 28,3 | 31,7 | 33,3 | 35 | 38,3 | |
ME30KX100-100/2 | • | 22 | [Hm] | 77 | 77 | 69 | 62,5 | 60 | 54 | 50,5 | 46,5 | 38 |
ME35KX100-100/2 | • | 26 | [Hm] | 83 | 83 | 77,5 | 72 | 70 | 64 | 60,5 | 57 | 48 |
ME40KX100-100/2 | • | 30 | [Hm] | 90 | 90,5 | 86 | 82 | 80 | 74,5 | 71 | 67,5 | 59 |
ME50KX100-100/2 | • | 37 | [Hm] | 100,5 | 100 | 99 | 95,5 | 94 | 89 | 85,5 | 82 | 73 |
ME60KX100-100/3 | • | 45 | [Hm] | 135 | 135 | 127,5 | 120 | 117 | 108,5 | 103,5 | 98,5 | 86 |
ME75KX100-100/3 | • |
55 | [Hm] | 150,5 | 150 | 146,5 | 143 | 140,5 | 133,5 | 128,5 | 123 | 110 |
ME75KX100-100/4 | • | 55 | [Hm] | 174,5 | 174 | 162,5 | 152 | 147,5 | 136 | 129 | 122 | 104,5 |
ME100KX100-100/4 | • | 75 | [Hm] | 198,5 | 198 | 195,5 | 190 | 187 | 177,5 | 171 | 164 | 146,5 |
ME100KX100-100/5 | • | 75 | [Hm] | 225,5 | 224,5 | 213 | 200,5 | 195,5 | 181 | 173 | 164 | 143 |
ME125KX100-100/5 | • | 90 | [Hm] | 243,5 | 242,5 | 238,5 | 230 | 225 | 212 | 203,5 | 194,5 | 172 |
Viskositet 1 mm²/s
Temperatur 20°C,
η% - Pump effektivitet, Y Ventilförlust returnerar inte.